酒泉防火玻璃棉板玻璃絲棉板區別
高溫玻璃棉施工建議
在設備表面提前焊上銷釘,再用鐵絲把高溫玻璃棉捆綁在設備表面,當所需保溫的設備溫度超過250℃時,采用雙層保溫方式,內外兩層玻璃棉的接縫應錯開,以免產生熱橋造成熱量損失。當所需保溫的設備溫度超過400℃時,建議內層用一定厚度的硅酸鋁,外層用耐高溫玻璃棉,兩層之間的接縫也應錯開。zui后在外面包上外裹層,既可保護玻璃棉,又達到美觀的要求。報價:王
First, weld pins to the surface of the equipment in advance and then tie the refractory glass wool over the surface of the equipment. If temperature of the equipment is above 250℃, it is recommendable to adopt double-layer heat preservation method. Make sure that the seams of the outer and inner layers of glass wool are staggered to avoid heat loss due to the heat bridge formed. If temperature of the equipment exceeds 400℃, it is recommendable to use aluminum silicate for the inner layer and refractory glass wool for the outer layer, also staggering their seams. Finally, wrap the outer cover layer which serves both as protection to the glass wool and decoration.
超細玻璃棉主要物理性能指標
項目 | 單位 | 指標 | 標準 |
密度 | Kg/m3 | 10-100 | GB/T 5480.3-1985 |
纖維平均直徑 | μ m | 5.5 | GB/T 5480.4-1985 |
含水率 | % | ≤1 | GB/T 3007-1982 |
燃燒性能級別 |
| 不燃* | GB 8624-1997 |
熱荷重收縮溫度 | ℃ | ≥250 | GB/T 11835-1988 |
導熱系數 | w/m·k | 0.038-0.06 | GB/T 10294-1988 |
憎水率 | % | ≥98.2 | GB/T 10299-1988 |
吸濕性 | % | ≤5 | GB/T 16401-1986 |
吸聲系數 |
| 1.03產品混聲定法 | GBJ47-83 |
渣球含量 | % | ≤0.3 |
|
玻璃棉板產品規格
產品 Product | 長度(mm) Length | 寬度(mm) Width | 厚度(mm) Thickness | 密度(Kg/m3) Density |
板材 Boards | 1200-2200 | 600-1200 | 20-100 | 24-96 |
卷氈 Blanket rolls | 11000,20000 | 1200 | 25-150 | 12,16,20,24,32,40,48 |